Air Handling Fans
Ring Type Axial Fans
Blades Impeller | 4,6,7,8 & 11 |
Sizes | 300 mm to 1600 mm |
Electric Current Type | AC |
Blade Material | SS |
Product Type | Duct Mounted Fan |
Air Volume | Upto 130000 CHM |
Features:
- Low maintenance
- Easy to install
- Low power consumption
Jet Axial Fan
Surface Finishing | Powder Coated |
Voltage | 340 V |
Electric Current Type | AC |
Product Type | Duct Mounted Fan |
Power Source | Electric |
Phase | Single Phase |
Jet axial fans and induction fans at air entry and exit points create the induction phenomenon, extracting the air and smoke from the area. This ventilation system is based on the impulsion of a small amount of air at a high speed, which homogenizes the rest of the air. Jet axial fan system also makes it possible to keep polluting gases at low concentration levels without the need to start up the whole of the car park’s ventilation system. By starting up just the induction fans, in combination with designing zoned or staged ventilation systems and a gas detection system, it is possible reduce power consumption and noise levels, and to extend the useful life of the equipment. With impulsion ventilation, it is possible to design smoke control systems to be used when there is a fire and which satisfy.
Exhaust Axial Flow Fan
Blade Material | Cast Iron |
Usage/Application | Industrial |
Type | Wall Mounted Fan |
Mounting | Duct Fan |
Electric Current Type | AC |
Brand | Teral-Aerotech Fans |
Fan Speed | 1440 RPM |
Voltage | 415 V |
Product Type | Duct Mounted Fan |
Features:
- Low maintenance
- Sturdy
- Rust-proof
Induced Draft Fan
Capacity | Up to 80,000 CMH |
Type | Duct Mounted Fan, V-Belt Driven Units |
Temperature Range | Up to 500A Degree C |
Static Pressure | Up to 350 mm WG (3500Pa) |
We manufacture and suppliers of superior quality Induced Draft Fan commonly known as ID Fan are available in wide range of capacity and pressure at elevated temperature to exhaust or recalculate high temperature gases/flue gases. Induced Draft Fan can be used with Boiler, Oven, Furnace etc. Induced blower fan is available in direct driven and V-Belt driven. The Plug Fan is used to recalculate in oven to achieve require temperature. The drive and material of construction are based on operating temperature.
Induced Draft (ID) fans are used to create a vacuum or negative air pressure in a system or stack. Our centrifugal blowers are used to maintain elevated ventilation, resulting in increased system efficiency. Teral-aerotech fan also suppliers extractor fans, which are typically heavy duty construction to handle particulate in the air stream. In the boiler industry ID Fans are often used in conjunction with FD fans to maintain system pressure which is slightly lower than ambient.
Working Principle:
Induced draft Fan is also used to identify the combustion process used in large boilers. When mechanical ventilation is supplied to these boilers, the heat transfer rate increases. Induced draft fan or ID fan is always located between dust collector and chimney. ID fan takes the hot flue gases from furnace via dust collector (dust separation system or Fume Extraction system) and will deliver to chimney. ID fan produce the pressure lower than the atmospheric pressure in the system or we may say that ID fan produces the negative pressure in the furnace to remove the flue gases from furnace via Multi Cyclone and to push the flue gases to chimney.
Man Cooler Fan
Product Brochure
Sweep | 300 mm |
Motor | 0.5 H.P |
Power Source | Electric |
Material | Stainless Steel |
Speed | 2850 RPM |
Teral-Aerotech is affianced in manufacturers of supreme quality Industrial Man Cooler Fan. This man cooler fan is widely used to expel the air from a ventilation system. By following the modern engineering concepts, our skilled professionals design this cooler fan using optimum grade components with the help of advanced technology. Further, our team of experts checks the quality of the Industrial Man Cooler Fan on different standards. Patrons can avail this man cooler fan in various technical specifications from us at nominal rates.
Man cooler s fans as they’re typically observed, were developed primarily for purpose cooling of persons and machinery in industrial environments wherever no or little ventilation exists. Man cooler fans are designed to stay the body temperature operating in working industrial unit, cool. due to automation everywhere the words, industrial units are becoming quick automation.
Man cooler fans clearly describes what this kind of fan’s use is meant for. The fan is nearly forever positioned near the persons or instrumentation requiring cooling. Man cooler fans common use for this kind of fan is in enveloped areas wherever there’s no ventilation or in areas which can need temporary cooling for persons operating in extreme non louvered very popular conditions.
Features :
- High performance
- Long service life
- High strength
- Energy efficiency
Applications :
- All shop floors, especially those with furnaces, foundries and heat/fume producing units.
- Factories with large number of workers and machines in a single room.
- Cooling of brick kilns, bottles in glass works, electrical equipments, tempering furnaces etc.
- Industrial cooling of castings, generators and other machines.
- Dehydration in cold storages.
- Spot cooling of man, machine and material.
Our Specialty :
- High power air stream/velocity.
- More angular swing and vertical tilt.
- Lower noise level.
- Dynamically balanced impellers.
- Compact design for restricted space.
- Corrosion free parts.
- Excellent finish with matching colors.
- Minimum power consumption.
- Trouble free operation.
- Prompt after sales service.
- Affordable prices.
High Pressure Fan
Brand Name | Teral-Aerotech Fans |
Surface Finishing | Powder Coated |
Voltage | 320 V |
Frequency | 50 Hz |
Material | SS |
Tube Axial Fan
Type | Duct Mounted Fan |
Electric Current Type | AC |
Blade Material | SS |
Impeller Size | 585 mm |
Product Type | Wall Mounted Fan |
Body Material | Mild Steel |
Tube Axial Fans in seven different models, belt drive and direct drive, with spark resistant cast aluminum propellers, steel propellers, and stainless steel propellers. Fans entirely of stainless steel are also available. The spark resistant cast aluminum propeller is often a standard requirement for paint spray booth exhaust applications as well as other exhaust applications.
Tube axial Fans are designed for moderate pressure ventilation and industrial process applications where axial flow fan is desirable and space is at a premium. Uses include heat, smoke and fume removal, process-drying with ambient or preheated air, comfort and process cooling and general ventilation.
Tube Axial fans for the cooling of electronic equipment are equipped with external housing and an electric motor integrated into the fan hub. This compact construction allows space-saving accommodation of all devices and easy installation; the flange is equipped with mounting holes. Taral-aerotech fans are available in various tube axial fans manufacturers in India.
Feature :
- Loft mounting
- Bathrooms and toilets
- Shower cubicles
- Underground floors
Additional Information:
- Production Capacity: 1 - 2 Weeks
- Delivery Time: 1 - 2 week
Tubular Mounted ManCoolers
Power Source | Electric |
Phase | Single Phase |
Mounting Type | Tubular |
Voltage | 340 V |
Frequency | 50 Hz |
Teral-aerotech offered a wide range of Tubular Mounted Man Coolers and we use premium quality raw materials in the fabrication of man cooler fans which are acquired from some of the most reliable vendors in the market. Teral-aerotech man coolers manufactured carry distinctive value and appeal in the mind of our customers which makes them one of the most competitive products in the market. We offer a wide range of man cooler fans that differ in the mechanism of their working. Our man cooler fans product range include tubular, column and pedestal type designs which are differently designed to meet variable requirements in the market.
The Tubular Man Cooler Fans is mounted on a cradle with casing. Fitted with aerofoil blades of cast aluminum alloy, it is designed for high efficiency and long distance air throw. A simple mechanism allow you to adjust the air stream angle as required.
Teral-aerotech fans are widely used in different industries. We manufacture the fans using high grade raw material that ensures better quality and durability. We do not compromise with the quality of these fans and so we test these fans on different quality parameters for flawless performance.
Double Inlet Fan
Brand Name | Teral-Aerotech Fans |
Electric Current Type | AC |
Voltage | 240 V |
Frequency | 50 Hz |
We also Export and Supply Forward Curve Centrifugal Air Fan/Blowers-Double Inlet Double Width(DIDW) to the TRADERS, Manufacturing and Trading companies/firms, Wholesaler, Distributors in different parts of India and also outside India, as per there requirements.